Instruction manual
-4-
JUNCTION BOX INSTALLATION TYPES
2S FITTING
a. 2S Fitting requires only 2pcs of 2S/4S
screws.
Note: You have a reduced space in which
to hide cables using this type of
installation. Recommended for indoor
dome only.
TWO GANG FITTING
a. Two gang tting (switch box) requires 4pcs
of 2S/4S screws.
Note: A two gang provides the most robust
tting. Suitable for both indoor and
vandal domes.
4S FITTING
a. 4S Fitting requires 2pcs of 2S/4S screws.
Note: Screws used for the 4S box are larger
compared to those used for the 2S (M4
type). Suitable for both indoor and
vandal domes
OCTAGON FITTING
a. 4” Octagon tting requires only 2pcs of
Octagon screws.
Note Screws used for the octagon tting
are larger compared to those used for
the 2S/4S (M4 type). Suitable for both
indoor and vandal domes
Cable
Entry
Screws
Cable
Entry
Screws
Cable
Entry
Screws
Cable
Entry
Screws