9.3 Trigger
FDwfDigitalInTriggerSourceInfo(HDWF hdwf, int *pfstrigsrc)
Parameters:
- hdwf Interface handle.
- pfstrigsrc Variable to receive the supported trigger sources.
The function above returns the supported trigger source options for the instrument. See the description of
FDwfDeviceTriggerInfo.
FDwfDigitalInTriggerSourceSet(HDWF hdwf, TRIGSRC trigsrc)
Parameters:
- hdwf Interface handle.
- trigsrc Trigger source to set.
The function above is used to set the trigger source for the instrument.
FDwfDigitalInTriggerSourceGet(HDWF hdwf, TRIGSRC *ptrigsrc)
Parameters:
- hdwf Interface handle.
- ptrigsrc Pointer to variable to receive the trigger source.
The function above is used to get the current trigger source setting for the instrument.
FDwfDigitalInTriggerPositionInfo(
HDWF hdwf, unsigned int *pnSamplesAfterTriggerMax)
Parameters:
- hdwf Interface handle.
- pnSamplesAfterTriggerMax Variable to receive the maximum trigger position.
The function above returns maximum values of the trigger position in samples. This can be greater than the
specified buffer size.
FDwfDigitalInTriggerPositionSet(HDWF hdwf, unsigned int cSamplesAfterTrigger)
Parameters:
- hdwf Interface handle.
- cSamplesAfterTrigger Samples after trigger.
The function above is used to set the number of samples to acquire after trigger.