User Manual

1-Aug-2012
32
Tolerance
o 1.0V Vccint 0.95 to 1.05V
o Vccaux +/- 5%
o Vcco +/-5%
Ramp time
o 0.20 to 50ms
o In-rush current must be controlled so the power circuitry is not overloaded at
start-up
Monotonicity
o No negative dips in Vccint or Vccaux power-up ramps
Sequencing
o Verify sequencing responds as expected based on design
Refer to Zynq Datasheet for the latest requirements
2.11.8 Probes
Two ground test point are available on the board, J3 and J4. This allows easy access to attach
ground leads of two scope probes to the board without having to locate GND pins on a header.