Copyright Digilent, Inc. All rights reserved. Other product and company names mentioned may be trademarks of their respective owners.
Figure 1 Power-Up Sequence
Description Min Max
Unit
t1
TFT-EN high to first
pixel bus signal
0.05
100
ms
t2
Valid pixel data to DISP
high
0 200
ms
t3
DISP high to backlight
on;
backlight off to DISP
low
160
ms
t4
TFT-EN low pulse 100
ms
Table 1 Power-Up/Reset Timing
Video Timing
To display an image, the LCD needs to be
continuously driven with properly-timed data.
This data consists of the lines and blanking
periods that form video frames. Each frame
consists of 272 active lines and several vertical
blanking lines. Each line consists of 480 active
pixel periods and several horizontal blanking
periods.
Parameter
Description Value
Unit
fCLK Pixel clock 9 MHz
tVA Vertical active
period
272 lines
tVB Vertical
blanking
period
16 lines
tHA Horizontal
active period
480 CLK
periods
tHB Horizontal
blanking
period
45 CLK
periods
Table 2 Typical LCD Video Timing Parameters
Figure 2 Video Timing
Video data is sent on a parallel interface
synchronous to CLK. The table below lists the
timing parameters of this interface. “Data”
refers to the combined pixel data from the R,
G, and B pins.