Operating instructions
8 - 12
MAN0443.P65 Issue 13 Aug 04 5701 Control System
05701-M-5001 A02279
CHAPTER 8 - SPECIFICATION
A
31.8
5.9
43.6
8.4
B
Leakage Current: 0.75mA maximum per 50W Module.
Overload Protection: Operates at more than 105% of rated
full load and recovers automatically.
Safety Approvals: 50W Module approved to UL1950,
IEC950, CSA 22.2 No 234.
Output Voltage: 24V ± 10% dc.
Output Configurations:
Half 19'' Rack: 50W or 100W.
Full 19'' Rack: 50W, 100W, 150W or 200W.
Earthing Point: M5 stud.
Weight:
Half 19'' Rack 50W: 900g.
Full 19'' Rack 50W: 960g.
50W Module: 230g.
Sub Unit: 815g.
Dimensions:
PSU Assembly A B Clearance
Width Height
8 Way 279.4 261.9 222 41
16 Way 482.6 465.1 443 41