SAMPLE RATE sets the sample rate when Clock Source is set to Internal. Range: 44.1 / 48 / 88.2 / 96 kHz.
■
SAMPLE RATE MODE sets the MADI mode for 88.2 / 96 kHz operation; check your console manual for the proper selection.
Range: High Speed, SMUX.
■
STATUS displays synchronization status (Sync or No Sync).
■
CURRENT CLOCK SOURCE IS displays the current sync method.
■
SoE displays Sync over Ethernet status (On or O).
■
CLOCK SOURCE AUTO-SWITCHING allows the MGB/MGO driver to switch between clock sources if it nds a higher priority
source than the currently selected source. Sync priority order is: SoE, WC, Digital 1, Digital 2, and Internal.