Specifications

61
DIGIGRID DLS/DLI
Sample Rate Master
SoundGrid Studio and the SoundGrid driver can set the sample rate of the clock master DLI/DLS. For example, when you open a
DAW session at sample rate dierent from the current SoundGrid Studio sample rate:
DAW requests SoundGrid driver to change sample rate.
SoundGrid driver instructs SoundGrid Studio. If SoundGrid Studio is set as Sample Rate Master, then it requests master clock I/O
to change its sample rate.
All slaved I/O devices adjust their sample rates accordingly.
When the master device (DLI/DLS in this case) clock is set to Internal, sample rate can be set from the drop-down Sample Rate
menu in the SoundGrid Studio application.
Sample Rate Slave
SoundGrid Studio and the SoundGrid driver will follow the DLI/DLS sample rate, as set by the selected clock source.
The same request is made as above, but SoundGrid Studio is set to Sample Rate Slave:
DAW requests SoundGrid driver to change sample rate.
SoundGrid driver noties SoundGrid Studio. SoundGrid Studio is set to Sample Rate Slave, so it cannot request a system sample
rate change. The master clock I/O does not change its sample rate.
All slaved I/O devices follow the master and do not change sample rate.
The SoundGrid Driver denies the sample rate change request from the DAW. The DAW will prompt an error in such a case (this
may vary between DAWs).
In Slave mode, all sample rate changes must originate from the clock master device.