Specifications
47
DIGIGRID DLS/DLI
4.3.3 Adding More DigiLink-Compatible I/O Devices to a DLI/DLS: SGP Mode
You can connect up to four DigiLink-compatible I/O devices to each DLI/DLS. Each DigiLink-compatible I/O provides 16 channels.
Each DLI/DLS port can provide 32 channels, so the conīguration in this illustration provides 64 channels.
Connections:
DLI/DLS Port > 192 #1 Primary Port > 192 #1 Expansion Port 192 #2 Primary Port
DLI/DLS Port 2 > 192 #3 Primary Port > 192 #3 Expansion Port >192 #4 Primary Port
The four DigiLink-compatible I/O devices are clocked to each other through Loop Sync. The DLI/DLS receives clock from the loop
master, directly from the DL cable.
DigiLink Interface
Primary Port Expansion Port
Primary Port Expansion Port
In Out
DigiLink Interface
Primary Port Expansion Port
In Out
DigiLink Interface
Primary Port Expansion Port
In Out
DigiLink Interface
In Out
DL1 DL2
WC / Loopsync*
WC / Loopsync*
WC / Loopsync*
WC / Loopsync*
DiGiGrid DLS
Ethernet
DigiLink
Clock
* Dependent on Clock
Mode setting in the DLS/
DLI control panel