Technical information
www.fagerhult.com • www.fagerhult.co.uk458
Dimming
DALI – components
DALI Touch panel DIGIDIM 200-series control panels DIGIDIM 312 multi-sensor
DALI MCU rotary potentiometer
DALI SC – scene module
DIGIDIM 444 – input unit
Components from Helvar
Control panels 200-series (white thermoplastic)
Designation Function
DIGIDIM 126200 Control panel with 8 controls 86143
DIGIDIM 125200 Control panel with 7 controls 86137
DIGIDIM 100200 Control panel with rotary controls 86144
DIGIDIM 111200 Control panel with 2 sliders 86145
Phase regulators
DIGIDIM 452 Leading and trailing edge control, max 1000 W 86146
Multisensor
DIGIDIM 312
For constant light, with occupancy detection and
IR-receiver. Recessed mounting, cut out Ø 55 mm
86122
Power supply
DIGIDIM 402 Supplies max 250 mA to the control circuit 86123
Remote control
DIGIDIM 303 IR-remote control 86121
Relay & input unit
DIGIDIM 494 For max 10 A resistive load or 6 A inductive load 86147
DIGIDIM 444 Input unit for optional switches or other control 86148
Gateways
DIGIDIM 472 Converts DALI to 1–10 V DC, DIN rail mounting 86136
DIGIDIM 410 For connecting a DALI-system to 1–10 V DC 86120
DIGIDIM 430 For connecting a DALI-system to LonWorks 86149
Interface
DIGIDIM 505
Serial interface for PCs. Used together with the Helvar
Toolbox software
86124
Components from Osram
Rotary potentiometer
Designation Function
DALI MCU rotary
potentiometer
Rotary potentiometer with integrated power supply for
25 DALI units. 86212
Note: It is not possible to mix control components from dierent manufacturers
in the same DALI-system.
Components from Fagerhult
Control panels
Designation Function
DALI Touch panel Programmable DALI panel with pushbuttons. 18595
DALI Touch panel
Fagerhult has designed and developed a
pushbutton panel oering unique func-
tions and options. Originally the panel
was developed to meet the requirements
of a hospital environment where the label
on each individual pushbutton needs to
be easy to read.
Pushbuttons for lighting control can be
designed for a variety of environments
and needs. Being able to see the various
functions and which was most recently
activated always comes down to two
fundamental requirements.
A pushbutton panel that has a number
of buttons must have diodes to show the
selected function, as well as clear, legible
text indicating the function of each
button. This panel also has membrane
pushbuttons, which are easy to clean. To
identify each function simply print out
the required text using a labelling device
such as DYMO or Brother, 8 mm text
width. The text strip should be applied
from the reverse side of the panel before
fitting. NB! do not remove the cover strip
on the tape side!
DIGIDIM 200-series panels
Control panels for assembly in standard
pattress boxes. Face of white thermoplas-
tic. The pushbuttons’ or controls’ func-
tions can be programmed to control an
individual luminaire, a luminaire group, a
complete DALI-system or recall a pre-set
lighting scene.
DIGIDIM 452
Digital single channel phase regulator for
incandescent and halogen lamps. Leading
and trailing edge control can be selected
using a switch. Lacks a power source for
DALI. For 230–240 V/50–60 Hz.
DIGIDIM 312 multi-sensor
Multi-sensor with the functions (selecta-
ble) constant light, occupancy detection
and receiver for remote control (IR). The
unit is recess mounted. Hole diameter
55 mm. Sensing range 50–5000 lx, 100
or 40 degrees detection and elliptical
sensing area.
DIGIDIM 444 input unit
The input unit allows the connection of
optional switches or other external con-
nections to a DALI system.
DIGIDIM 402 power supply
Power source for DALI. For DIN rail mount-
ing. 220–240 VAC, 50–60 Hz.
DIGIDIM 303 IR-transmitter
For scene selection and/or channel con-
trol. Can also be used as a programming
unit on installations with luminaires
equipped with a Helvar DIGIDIM system.
Requires the system to be equipped with
Helvar’s wall panel or multisensor with
IR-receiver.
DALI SQM sequence module
For automatic sequence control of DALI
units, e.g. LEDs with RGB colours. The
unit alternates light scenes which must
be pre-programmed using the DALI DI-
GIDIM Toolbox or WinDIM software. The
sequence can be started/stopped by an
external function such as a time switch.
DALI SC
Four scene control module for push-
button mounted in pattress box. Installed
in the pattress box behind the switch.
Suitable push-buttons are standard
momentary heavy current switches from
various suppliers.
DALI GC
Two channel control module for push-
button mounted in a pattress box.
Installed in the pattress box behind the
switch. Suitable push-buttons are stand-
ard momentary heavy current switches
from various suppliers. Capable of ignit-
ing, extinguishing, dimming, addressing
and grouping the DALI system.
DALI PS1
Compact and enclosed power source
for DALI that can be fitted, for example,
in a suspended ceiling. 120–240 V AC,
50–60 Hz.
Rotary potentiometer DALI MCU
Rotary potentiometer with built-in power
supply to 25 DALI devices. Connected
to 230 V and DALI. Two MCU can be
connected to power to a maximum of 50
DALI devices. Four potentiometers can
be connected in parallel for control from
multiple locations. Potentiometers MCU
should not be combined with other DALI
controllers.
Subject to alteration. For further specifi-
cations see www.helvar.com and
www.tridonicatco.com.
Components from Tridonic
Control panels
Designation Function
DALI GC Two channel control module. For use with standard mo-
mentary heavy current switches from various suppliers.
Installed in the same box as the push-button. 86125
DALI SC Control module for four scenes. For use with standard
momentary heavy current switches from various suppli-
ers. Installed in the same box as the push-button. 86126
Power supply
DALI PS1 Supplies 200 mA to the control circuit 86127
DALI sequence module
DALI SQM For automatic sequence control of DALI units, e.g. LEDs
with RGB colours. 86214
Interface
DALI SCI Serial interface for PCs. Used together with the Tridonic
winDIM software. 86129
DALI USB Interface for Tridonic software WinDIM and ConfigTool.
Connects to the PC’s USB port. Replaces the previous
DALI SCI except when using the Light Over Time func-
tion. 86182
Note: It is not possible to mix control components from dierent manufacturers
in the same DALI-system.
For more information go to www.barbourproductsearch.info