Specifications

SYNC I/O Guide64
6 When you reach a value that matches the
sticker’s value, stop scrolling and press Set. The
LED Time Code Display will return to showing
time code numbers. Your SYNC I/O is now prop-
erly calibrated.
The next time you press Set, the LED Time Code
Display will again show O5C CAL. If you then
press the Down switch, you’ll disengage the Os-
cillator Calibration parameter name. To change
the setting once again, you’ll need to repeat
steps 1 through 6.
Restoring Factory Settings
SYNC I/O can be reset to its default factory set-
tings.
To reset all parameters to default settings:
1 Switch off power to SYNC I/O and wait at least
10 seconds.
2 Hold down the Up and Down front panel
switches and turn on power to SYNC I/O. Do not
release the Up and Down switches until the dis-
play reads FAC-CFG.
Factory Default Settings
The following table lists the default settings of
each parameter.
Resetting factory settings does not reset the
SYNC I/O oscillator. See “Calibrating the
SYNC I/O Oscillator” on page 63 for infor-
mation.
SYNC I/O Defaults
Parameter Name Default
Set Generator Start Time
00:00:00:00
Digital Reference
AES/EBU
Sample Freq (Rate)
44.1 kHz
VITC Insertion
On
Pull Rates
Off
Base Clock
Session (1x Word)
(VITC) Reader Line
All
(VITC) Generate Line
14–16
Window Burn On/Off
On (Enabled)
Freewheel Duration
8 frames
LTC Output gain
3 dBu
Servo gain
–001
Pitch Hold
Off
Bi-Phase Pulse-per-frame
0100
Bi-Phase Signal
A Lead B
Video System/Format
NTSC
Idle MTC Enabled
On
Window Burn options:
Enabled
Size: Large
Ver tical Position: 20%
from Bottom
Horizontal Position: Center
Color: White on Black
background
Variable Speed Offset
(VSO)
Off