Specifications
SYNC I/O Guide24
Sample Rate LEDs
These green or yellow LEDs show the current
SYNC I/O sample rate. Pull Up and Pull Down
are available for all sample rate settings, indi-
cated by the corresponding LED. Table 4 (above)
shows the actual sample rates when pulled up or
down.
Generator/Parameter Controls
These four switches provide direct access to
many SYNC I/O functions, including time code
generator settings, PAL/NTSC selection, sample
rate and more. The Time Code LED display
shows the current mode, selected parameter, or
setting.
Time Code Display
This 7-segment, multifunction LED is the
SYNC I/O time code and parameter display.
Time Code The current positional reference (in-
ternal or external), is displayed in hours:min-
utes:seconds:frames. Odd/even field distinction
is indicated using a decimal point to the right of
the frames display. A lit decimal point to the
right of frames indicates an even-numbered
field; no decimal point indicates an odd-num-
bered field. When SYNC I/O is in Auto Switch
LTC/VITC mode, the decimal point to the right
of “minutes” illuminates.
The SYNC I/O Time Code Display always dis-
plays actual incoming time code, regardless of
any Session Start Offsets (External Time Code
Offsets in Pro Tools 6.6.x) that are applied in
Pro Tools.
Table 4. Sample Rates at Pull Up and Pull Down Settings
Pull Up/Down
Sample Rate
44100 48000 88200 96000 176400 192000
+4.1667%
and +0.1%
45983 50050 91967 100100 n/a n/a
+4.1667% 45938 50000 91875 100000 n/a n/a
+4.1667%
and –0.1%
45892 49950 91783 99900 n/a n/a
+0.1% 44144 48048 88288 96096 176576 192192
–0.1% 44056 47952 88112 95904 176224 191808
–4.0% and
+0.1%
42378 46126 84757 92252 n/a n/a
–4.0% 42336 46080 84672 92160 n/a n/a
–4.0% and
–0.1%
42294 46034 84587 92068 n/a n/a