Specifications
Chapter 2: Installation and Configuration
9
To connect SYNC I/O to Pro Tools|HD interfaces:
1
Using a BNC cable, connect the Loop Sync
Out of the SYNC I/O to the Loop Sync In of your
primary HD-series audio interface.
2
Connect the SYNC I/O Loop Sync In to the
Loop Sync Out of your HD-series interface.
When using more than one HD-series audio in-
terface, make SYNC I/O the first and last unit in
the Loop Sync chain.
Using Legacy Audio Interfaces with
Pro Tools|HD
If you are using a Pro Tools|HD system that in-
cludes a legacy audio interface (an 888|24,
882|20, 1622, or ADAT Bridge audio interface),
you will need to connect the Clock output of
the HD system to the Slave Clock Input of the
legacy interface.
To connect a legacy audio interface to an HD-
series system with SYNC I/O:
1
Connect SYNC I/O to the HD-series system
with Loop Sync as described in the previous
steps.
2
Using a BNC cable, connect the Ext Clock Out
of your primary HD-series interface to the Slave
Clock In of your first legacy interface.
3
If you are connecting multiple legacy inter-
faces, daisy-chain their Slave Clock connections
by connecting the Slave Clock Out of the first
interface to the Slave Clock In of the next inter-
face.
Connecting Slave Clock for
Pro Tools|24 MIX
To connect SYNC I/O to a Pro Tools|24 MIX-series
audio interface:
■
Using a BNC cable, connect the SYNC I/O
Word Clock Out to the Slave Clock In of your
primary audio interface.
Loop Sync connections between SYNC I/O and a 96 I/O
Loop Sync in an expanded Pro Tools|HD system
MTC OUT
HOST SERIAL
AC 100-240V, 50-60HZ, .5A 30W
VIDEO REF
9-PIN OUT 2
9-PIN OUT 1
WORD CLOCK (1x,256x)
VIDEO
L
T
C
I
N
A
E
S
I
N
A
E
S
O
U
T
L
T
C
O
U
T
IN
OUT
IN
OUT
IN
OUT
LOOP SYNC
INTERNALLY
TERMINATED
BI-PHASE / TACH / GPI / PILOT
SERIAL NUMBER
964530300294856
Loop Sync
SYNC I/O
Pro Tools 96 I/O
MTC OUT
HOST SERIAL
AC 100-240V, 50-60HZ, .5A 30W
VIDEO REF
9-PIN OUT 2
9-PIN OUT 1
WORD CLOCK (1x,256x)
VIDEO
L
T
C
I
N
A
E
S
I
N
A
E
S
O
U
T
L
T
C
O
U
T
IN
OUT
IN
OUT
IN
OUT
LOOP SYNC
INTERNALLY
TERMINATED
BI-PHASE / TACH / GPI / PILOT
SERIAL NUMBER
964530300294856
Clock for SYNC I/O, a 96 I/O, and an 888|24 I/O
See the Getting Started with HD Guide for
external clock configuration instructions.
Clock from SYNC I/O to an 888|24
Computer 1
ANALOG OUTPUT ANALOG INPUT AES/EBU OUTPUT AES/EBU INPUT
Computer 2
8 CH Mode
2 x 4 CH Mode
S/PDIF
IN
S/PDIF
OUT
SLAVE CLOCK
IN
SLAVE CLOCK
OUT
7
8
5
6
3
4
1
2
7
8
5
6
3
4
1
2
5/6
7/8
1/2
3/4
5/6
7/8
1/2
3/4
MTC OUT
HOST SERIAL
AC 100-240V, 50-60HZ, .5A 30W
VIDEO REF
9-PIN OUT 2
9-PIN OUT 1
WORD CLOCK (1x,256x)
VIDEO
L
T
C
I
N
A
E
S
I
N
A
E
S
O
U
T
L
T
C
O
U
T
IN
OUT
IN
OUT
IN
OUT
LOOP SYNC
INTERNALLY
TERMINATED
BI-PHASE / TACH / GPI / PILOT
SERIAL NUMBER
964530300294856
Computer 1
ANALOG OUTPUT ANALOG INPUT AES/EBU OUTPUT AES/EBU INPUT
Computer 2
8 CH Mode
2 x 4 CH Mode
S/PDIF
IN
S/PDIF
OUT
SLAVE CLOCK
IN
SLAVE CLOCK
OUT
7
8
5
6
3
4
1
2
7
8
5
6
3
4
1
2
5/6
7/8
1/2
3/4
5/6
7/8
1/2
3/4
MTC OUT
HOST SERIAL
AC 100-240V, 50-60HZ, .5A 30W
VIDEO REF
9-PIN OUT 2
9-PIN OUT 1
WORD CLOCK (1x,256x)
VIDEO
L
T
C
I
N
A
E
S
I
N
A
E
S
O
U
T
L
T
C
O
U
T
IN
OUT
IN
OUT
IN
OUT
LOOP SYNC
INTERNALLY
TERMINATED
BI-PHASE / TACH / GPI / PILOT
SERIAL NUMBER
964530300294856