1. Connect Primary Port A of the Delta-Link MADI HD to Primary Port A of your Pro Tools
®
HD system and Primary Port
B of the Delta-Link MADI HD to Primary Port B of your Pro Tools
®
HD system via DigiLink cables supplied. The Pro
Tools
®
software can be used to control internal settings of the Delta-Link Madi HD. This functionality uses Primary Port
A only, so it is important that this connection scheme is followed.
2. Connect a suitable Word or Frame clock source to the WordClock input at the rear of the Delta-Link MADI HD.
(see overleaf)
3. Connect the mains cable to the mains connector of the Delta-Link MADI HD.
4. External devices may now be connected to the MADI inputs and outputs.
5. Power up the computer that hosts your Pro Tools
®
system, and power up the Delta-Link MADI HD (using the power
switch on the front panel).
WARNING!
Do not connect or disconnect the Delta-Link MADI HD to/from the Pro Tools
®
cards or power cycle the unit
while the Pro Tools
®
software is running. Doing so will loose all interface settings, recovery from which will
require each option to be toggled on the Pro Tools
®
I/O set up page – refer to Section 6.