Specifications

MADI 700 Series Guide8
MA703 Back Panel
Input Voltage Selector This red switch sets the unit to either
110/115 VAC or 220/230/240 VAC environments. A fuse must
also be changed for 220/230/240 VAC operation. Units are
shipped set and fused for 110/115 VAC.
Power Connector (IEC) and Fuse Tray The IEC power connec-
tor accepts standard IEC power cords. The fuse tray contains
both the active and spare fuses. For information on changing
the fuse, see “220, 230, 240 VAC Operation” on page 2.
Analog Outputs (male XLR) 24 balanced analog outputs on
XLR connectors. Output level is set from the front panel.
Auxiliary Analog Outputs (male XLR) Two balanced analog out-
puts on XLR connectors. Output level can is set from the front
panel.
AES/EBU Digital Outputs (male XLR) Stereo AES/EBU digital
outputs on one XLR connector. Functions in parallel with the
auxiliary S/PDIF output and the two inputs should not be used
simultaneously.
S/PDIF Digital Outputs (RCA) Stereo S/PDIF digital output on
one RCA connector. Functions in parallel with the auxiliary
AES/EBU output and the two inputs should not be used simul-
taneously.
AES Sync In (female XLR) Master clock input for the converter
when using AES as the Sample Rate Source.
AES Sync Thru (male XLR) Outputs the same signal connected
to AES Sync In.
Word In (BNC) Master clock input for the converter when us-
ing Word Clock as Sample Rate Source.
Word Out (BNC) Outputs a Word Clock signal synchronized to
the Sample Rate Source. In the presence of an external Word
clock input, this connector provides a regenerated version of
the input signal. Without an external sample rate source, this
connector outputs an internally generated clock signal.
MADI In (BNC) Digital audio signal input.
1–24:analog outputs
25–26:aux analog outputs
27–28:aux digital outputs
MA703 Back Panel