Specifications

Chapter 6: Focusrite D2 53
Enabling, Disabling and Bypassing
EQ Filters
You can enable, disable, or bypass specific EQ
filters by clicking them.
To disable a filter:
Control-click (Macintosh) or Start key-click
(Windows) the EQ Filter icon. When disabled,
the icon is black.
To re-enable a filter:
Click the EQ filter icon. When enabled, the
icon is white.
To bypass a filter:
Click the EQ filter icon a second time. When
bypassed, the icon is grey.
Editing D2 Parameters Using a
Computer Keyboard
Each D2 rotary control has a corresponding pa-
rameter text field directly below or beside it.
This displays the current value of the parameter.
You can edit the numeric value of a parameter
with your computer keyboard.
To type a parameter value:
Click on the parameter text that you want to
edit. Type the desired value.
For parameters with values in kilohertz, typ-
ing “k” after a number value will multiply the
value by 1000. For example, to enter a value of
8000, type “8k.”
To increase a value, press the Up Arrow on
your keyboard. To decrease a value, press the
Down Arrow on your keyboard.
Press Enter on the numeric keyboard after typ-
ing a value to input the value.
Press Return (Macintosh) or Enter on the al-
pha keyboard (Windows) to enter the value and
leave Keyboard Editing mode.
To move forward through the different pa-
rameters, press the Tab key. To move backward,
press Shift+Tab.
If you are using all available bands of the
1–2 Band or 4–Band EQ and want to
change filter types, you must disable one fil-
ter before you can enable a different one.