User Guide
Getting Started with Digi 00286
Digital Clock Source
When you connect an external digital source,
you can set Digi 002 to synchronize to external
Word Clock (the clock signal coming from the
device) or internal Word Clock (generated by
Digi 002). In most cases, such as with DAT
decks, you will use external clock.
To change the clock source for the digital inputs
on Inputs 5–6:
1 In Stand-alone mode, press the Utility (F1)
switch.
2 Press the illuminated Channel Select switch
under Pref.
3 Press the illuminated Channel Select switch
under WClk (Word Clock).
4 Press the illuminated Channel Select switch
repeatedly to toggle the clock source to Internal
or S/PDIF (external).
5 Press the Escape switch to exit SPDF prefer-
ences.
6 Press the far right-hand Channel Select switch
to save the preference settings.
7 Press the Escape (Esc) switch twice to exit Util-
ity mode.
When the Word Clock source is set to S/PDIF
(external), the Sample Rate indicator flashes to
indicate that no clock signal is present, or that
Digi 002 is not receiving valid clock signal. The
Sample Rate indicator lights solid to indicate
Digi 002 is receiving valid clock signal.
Digital Outputs
The output configuration of Digi 002 in Stand-
alone mode depends on the digital output for-
mat chosen in the S/PDIF preference setting.
(This is the same setting used to configure the
digital input format.)
S/PDIF Outputs
In Stand-alone mode, the S/PDIF outputs on the
back panel of Digi 002 mirror outputs 1–2 at all
times. If RCA is chosen in the S/PDIF prefer-
ences, only the RCA S/PDIF connector is active.
If Optical is chosen in the S/PDIF preferences,
both the RCA and Optical S/PDIF connectors are
active.
If Optical is chosen in the S/PDIF preferences,
only Main Outputs 1–2 are mirrored in the Op-
tical Output port.
ADAT Optical Outputs
In Stand-alone mode, if RCA is chosen in the
S/PDIF preferences, all 8 Input channels are
passed directly to the ADAT Optical Output
port, pre-fader and pre-effects. This allows you
to route input signals directly to an ADAT device
and record raw input data on all 8 channels.
To change the digital output format:
1 In Stand-alone mode, press F1 (Utility).
2 Press the illuminated Channel Select switch
under Pref.
3 Press the illuminated Channel Select switch
under SPDF (S/PDIF).
4 Press the illuminated Channel Select switch
repeatedly to toggle the digital format to RCA or
Optical.
5 Press the Escape (Esc) switch to exit SPDF pref-
erences.
Digital output connectors (back panel)
S / PDIF
IN
OUT
OPTICAL
MIDI OUT 1MIDI OUT 2
IN
OUT
964530300294856
SERIAL NUMBER
RCA S/PDIF
Output
Optical
Output port