Product manual
XStream-PKG-R™ RS-232/485 RF Modem – Product Manual v5.x00
2.2. RS-485 (2-wire) Operation
2.2.1. DIP Switch Settings and Pin Signals
Figure 2.6. Figure 2.7.
RS-485 (2-wire) Half-Duplex Pins used on the female RS-232 (DB-9)
DIP Switch Settings Serial Connector
Figure 2.8.
RS-485 (2-wire) with Termination (optional)
Termination is the 120 Ω resistor between T+ and T-.
DIP Switch settings are read and applied only while powering-on.
Note: Refer to Figures 2.15 and 2.16 for RJ-45 connector pin designations used in
RS-485/422 environments.
Table 2.2. RS-485 (2-wire half-duplex) Signals and their implementations on the XStream RF Modem
DB-9 Pin
RS-485 Name
Description
Implementation
2 T/R- (TRA) Negative Data Line
Transmit serial data to and from the
XStream RF Modem
5
GND
Ground Signal
Ground
8 T/R+ (TRB) Positive Data Line
Transmit serial data to and from the
XStream RF Modem
9 PWR Power
Optional power input that is connected internally
to the front power connector
1, 3, 4, 6, 7
not used
Wiring Diagram: RS-485 (2-wire) Half-Duplex
Figure 2.9. XStream RF Modem in an RS-485 (2-wire) half-duplex environment
© 2014 Digi International Inc. 9