Product manual
XStream-PKG-R™ RS-232/485 RF Modem – Product Manual v4.2B5
4.3. Command Reference Table
Table 4.1 XStream Commands
(The XStream RF Modem expects numerical values in hexadecimal. “d” denotes decimal equivalent.)
AT
Command
Binary
Command
AT Command Name Range Command Category
# Bytes
Returned
Factory
Default
AT
0x05 (5d)
Guard Time After
0x02 – 0xFFFF (x 100 msec)
Command Mode Options
2
0x0A (10d)
BD v4.2B* 0x15 (21d) Interface Data Rate
Standard baud rates:
0 – 6
Non-standard baud rates:
0x7D – 0xFFFF
Serial Interfacing 2
Set to equal
factory-set RF
data rate
BT
0x04 (4d)
Guard Time Before
2 – 0xFFFF (x 100 msec)
Command Mode Options
2
0x0A (10d)
CC
0x13 (19d)
Command Sequence Character
0x20 – 0x7F
Command Mode Options
1
0x2B (“+”)
CD v 4.2B*
0x28 (40d)
DO3 Configuration
0 - 4
Serial Interfacing
1
0
CN
0x09 (9d)
Exit AT Command Mode
-
Command Mode Options
-
-
CS v 4.27D*
0x1F (31d)
DO2 Configuration
0 – 4
Serial Interfacing
1
0
CT
0x06 (6d)
Command Mode Timeout
0x02 – 0xFFFF (x 100 msec)
Command Mode Options
2
0xC8 (200d)
DT
0x00 (0d)
Destination Address
0 – 0xFFFF
Networking
2
0
E0
0x0A (10d)
Echo Off
-
Command Mode Options
-
-
E1
0x0B (11d)
Echo On
-
Command Mode Options
-
-
ER
0x0F (15d)
Receive Error Count
0 – 0xFFFF
Diagnostics
2
0
FH
0x0D (13d)
Force Wake-up Initializer
-
Sleep (Low Power)
-
-
FL
0x07 (7d)
Software Flow Control
0 – 1
Serial Interfacing
1
0
FT v 4.27B*
0x24 (36d)
Flow Control Threshold
0 – 0xFF (bytes)
Serial Interfacing
2
varies
GD
0x10 (16d)
Receive Good Count
0 – 0xFFFF
Diagnostics
2
0
HP
0x11 (17d)
Hopping Channel
0 – 6
Networking
1
0
HT
0x03 (3d)
Time before Wake-up Initializer
0 – 0xFFFF (x 100 msec)
Sleep (Low Power)
2
0xFFFF
ID v 4.2B* 0x27 (39d) Modem VID
User settable: 0x10 - 0x7FFF
Read-only: 0x8000 – 0xFFFF
Networking 2 -
LH
0x0C (12d)
Wake-up Initializer Timer
0 – 0xFF (x 100 msec)
Sleep (Low Power)
1
1
MK
0x12 (18d)
Address Mask
0 – 0xFFFF
Networking
2
0xFFFF
NB v 4.27B*
0x23 (35d)
Parity
0 – 4
Serial Interfacing
1
0
PC v 4.22*
0x1E (30d)
Power-up Mode
0 – 1
Command Mode Options
1
0
PW v 4.22*
0x1D (29d)
Pin Wake-up
0 – 1
Sleep (Low Power)
1
0
RE
0x0E (14d)
Restore Defaults
-
(Special)
-
-
RN v 4.22*
0x19 (25d)
Delay Slots
0 – 0xFF (slots)
Networking
1
0
RO v 4.2AA*
0x21 (33d)
Packetization Timeout
0 – 0xFFFF (x 200 µsec)
Serial Interfacing
2
0
RP v 4.2AA*
0x22 (34d)
RSSI PWM Timer
0 - 0x7F (x 100 msec)
Diagnostics
1
0
RR v 4.22*
0x18 (24d)
Retries
0 – 0xFF
Networking
1
0
RS v 4.22*
0x1C (28d)
RSSI
0x06 – 0x36 (Read-only)
Diagnostics
1
-
RT
0x16 (22d)
DI2 Configuration
0 - 2
Serial Interfacing
1
0
SB v 4.2B*
0x36 (54d)
Stop Bits
0 – 1
Serial Interfacing
1
0
SH v 4.27C*
0x25 (37d)
Serial Number High
0 – 0xFFFF (Read-only)
Diagnostics
2
-
SL v 4.27C*
0x26 (38d)
Serial Number Low
0 – 0xFFFF (Read-only)
Diagnostics
2
-
SM
0x01 (1d)
Sleep Mode
0 – 8
Sleep (Low Power)
1
0
ST
0x02 (2d)
Time before Sleep
0x10 – 0xFFFF (x 100 msec)
Sleep (Low Power)
2
0x64 (100d)
SY
0x17 (23d)
Time before Initialization
0 – 0xFF (x 100 msec)
Networking
1
0 (disabled)
TR v 4.22*
0x1B (27d)
Transmit Error Count
0 – 0xFFFF
Diagnostics
2
0
TT v 4.22*
0x1A (26d)
Streaming Limit
0 – 0xFFFF (0 = disabled)
Networking
2
0xFFFF
VR
0x14 (20d)
Firmware Version
0 x 0xFFFF (Read-only)
Diagnostics
2
-
WR
0x08 (8d)
Write
-
(Special)
-
-
* Firmware version in which command and parameter options were first supported.
NOTE: AT Commands issued without a parameter value will return the currently stored parameter.
© 2014 Digi International Inc. 24