User`s guide

XBee Sensor Adapter
45
Button
press
Network
association
Action
Single Associated If adapter is asleep, wakes unit for 30 seconds.
Sends a Node Identification broadcast transmission.
All devices that receive this transmission will blink their Associate LED rapidly
for 1 second.
All API devices that receive this transmission will send a Node Identification
frame out their UART (universal asynchronous receiver/transmitter) (API ID
0x95).
Unassociated If adapter is asleep, wakes unit for 30 seconds.
Blinks a numeric error code on the Assc LED, indicating the cause of join
failure.
1 blink: Scan found no PANs.
2 blinks: Scan found no valid PANs based on current SC (Scan Channel) and
ID (PAN ID) settings.
3 blinks: Valid Coordinator or Routers found, but they are not allowing joining
(NJ expired).
7 blinks: Node Joining attempt failed.
10 blinks: Coordinator Start attempt failed.
Two Associated Temporarily enables joining on the adapter and the entire ZigBee network for 1
minute (if the XBee module’s NJ command setting is less than 255). If joining is
permanently enabled on a module (NJ = 255), joining remains permanently
enabled, and this button press has no effect.
Four Associated/
Unassociated
Adapter leaves PAN, if associated, and issues a factory reset to restore default
parameters. Default PAN ID is 0x234.