DIP switches
The XBee RS-485 Adapter has several DIP switches on the underside of
the unit, with these settings:
Data retrieval
Retrieving data from XBee adapters is done by issuing a remote AT IS
(Force Sample) command through the XBee API. The XBee API and AT IS
command are described in detail in the XBee ZNet 2.5 (Series 2) RF
Module data sheet. AT IS commands can be issued via a Python program
that is executed on the gateway. See also the Product Manual for the XBee
Module and the Digi Python Programming Guide.
LEDs and buttons
DIP Switch Switch settings
1 Not used. It is covered up by the case and not
accessible.
2, 3, 4 ON = RS485
OFF = RS422
5, 6 ON = RS485 Bias and line termination on.
OFF = RS485 Bias and line termination off.
Note: Bias and line termination feature can be used
only when powering from the external power supply.
Assc
Ident
Power
blinking green
solid green
Reset button