AntennasapprovedforusewiththeXBee®/XBeePRO®RFModules(Cablelossisrequired)
*IfusingtheRFmoduleinaportableapplication(Forexample‐Ifthemoduleisusedinahandhelddeviceandtheantennaisless
than20cmfromthehumanbodywhenthedeviceisoperation):
TheintegratorisresponsibleforpassingadditionalSAR(Specific
AbsorptionRate)testingbasedonFCCrules2.1091andFCCGuidelinesforHumanExposuretoRadioFrequencyElectromagnetic
Fields,OETBulletinandSupplementC.ThetestingresultswillbesubmittedtotheFCCforapprovalpriortosellingtheintegrated
unit.The
requiredSARtestingmeasuresemissionsfromthemoduleandhowtheyaffecttheperson.
RF Exposure
WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of
20 cm or more should be maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this
transmitter must not be co-located in conjunction with any other antenna or transmitter.
The preceding statement must be included as a CAUTION statement in OEM product manuals in order to alert users
of FCC RF Exposure compliance.
Europe (ETSI)
The XBee RF Modules have been certified for use in several European countries. For a complete
list, refer to www.digi.com
If the XBee RF Modules are incorporated into a product, the manufacturer must ensure compliance
of the final product to the European harmonized EMC and low-voltage/safety standards. A
Declaration of Conformity must be issued for each of these standards and kept on file as described
in Annex II of the R&TTE Directive.
Part Number Type (Description) Gain Application* Min. Separation Required Cable-loss
A24-C1 Surface Mount -1.5 dBi Fixed/Mobile 20 cm -
A24-Y4NF Yagi (4-element) 6.0 dBi Fixed 2 m 8.1 dB
A24-Y6NF Yagi (6-element) 8.8 dBi Fixed 2 m 10.9 dB
A24-Y7NF Yagi (7-element) 9.0 dBi Fixed 2 m 11.1 dB
A24-Y9NF Yagi (9-element) 10.0 dBi Fixed 2 m 12.1 dB
A24-Y10NF Yagi (10-element) 11.0 dBi Fixed 2 m 13.1 dB
A24-Y12NF Yagi (12-element) 12.0 dBi Fixed 2 m 14.1 dB
A24-Y13NF Yagi (13-element) 12.0 dBi Fixed 2 m 14.1 dB
A24-Y15NF Yagi (15-element) 12.5 dBi Fixed 2 m 14.6 dB
A24-Y16NF Yagi (16-element) 13.5 dBi Fixed 2 m 15.6 dB
A24-Y16RM Yagi (16-element, RPSMA connector) 13.5 dBi Fixed 2 m 15.6 dB
A24-Y18NF Yagi (18-element) 15.0 dBi Fixed 2 m 17.1 dB
A24-F2NF Omni-directional (Fiberglass base station) 2.1 dBi Fixed/Mobile 20 cm 4.2 dB
A24-F3NF Omni-directional (Fiberglass base station) 3.0 dBi Fixed/Mobile 20 cm 5.1 dB
A24-F5NF Omni-directional (Fiberglass base station) 5.0 dBi Fixed/Mobile 20 cm 7.1 dB
A24-F8NF Omni-directional (Fiberglass base station) 8.0 dBi Fixed 2 m 10.1 dB
A24-F9NF Omni-directional (Fiberglass base station) 9.5 dBi Fixed 2 m 11.6 dB
A24-F10NF Omni-directional (Fiberglass base station) 10.0 dBi Fixed 2 m 12.1 dB
A24-F12NF Omni-directional (Fiberglass base station) 12.0 dBi Fixed 2 m 14.1 dB
A24-F15NF Omni-directional (Fiberglass base station) 15.0 dBi Fixed 2 m 17.1 dB
A24-W7NF Omni-directional (Base station) 7.2 dBi Fixed 2 m 9.3 dB
A24-M7NF Omni-directional (Mag-mount base station) 7.2 dBi Fixed 2 m 9.3 dB
A24-P8SF Flat Panel 8.5 dBi Fixed 2 m 8.6 dB
A24-P8NF Flat Panel 8.5 dBi Fixed 2 m 8.6 dB
A24-P13NF Flat Panel 13.0 dBi Fixed 2 m 13.1 dB
A24-P14NF Flat Panel 14.0 dBi Fixed 2 m 14.1 dB
A24-P15NF Flat Panel 15.0 dBi Fixed 2 m 15.1 dB
A24-P16NF Flat Panel 16.0 dBi Fixed 2 m 16.1 dB
A24-P19NF Flat Panel 19.0 dBi Fixed 2 m 19.1 dB