Product manual
XBee®/XBee‐PRO®RFModules‐802.15.4‐v1.xEx[2009.09.23]
©2009DigiInternatonal,Inc. 55
ST (Time before Sleep) Command
<Sleep Mode (Low Power)> The ST command is
used to set and read the period of inactivity (no
serial or RF data is sent or received) before acti-
vating Sleep Mode.
NonBeacon Firmware
Set/Read time period of inactivity (no serial or RF
data is sent or received) before activating Sleep
Mode. ST parameter is only valid with Cyclic Sleep
settings (SM = 4 - 5).
Coordinator and End Device ST values must be equal.
AT Command: ATST
Parameter
Range:
NonBeacon Firmware:
1 - 0xFFFF [x 1 millisecond]
Default Parameter Value:
Related Commands: SM (Sleep Mode), ST