Specifications
Wavespeed/S Configuration Guide (90000407 Rev. C) – Page 5 
10.  The Configuration Wizard automatically notifies you 
that the bonding was successful. If the procedure fails, 
retry the bonding process. 
11.  Click Next when bonding is complete. 
Configure Local Port Settings 
The next step is to specify the local device’s port emulation 
settings and type. In this step, you will specify how the 
Wavespeed/S device communicates over the COM port to the 
device it is attached to. In other words, if your application cur-
rently sends data at 9600 baud with 8 data bits, 1 stop bit, no 
parity, and software flow control, you need to specify those 
settings for the Wavespeed/S. In addition, you must determine 
if the device attached to the Wavespeed/S is a DTE or DCE 
device. The Wavespeed/S device must be set to the device type 
that is opposite of the device to which it will be attached. That 
is, if your device is DTE, select DCE for the Wavespeed/S. 
12.  For each port setting, select the desired value.  
13.  Clicking Advanced allows you to set the following: 
  SPP  Connect Output Select: The SPP 
Connection Status Signal is a unique feature that 
raises the voltage level of Pin  1  (carrier detect) 
when a SPP connection is present on the 
Wavespeed/S. Application developers can see if a 
connection is available simply  by checking the 
status of Pin 1. This feature is available when the 
unit is configured as a DCE device. 
14.  When all settings are specified, click  Set Port 
Configuration to send the settings to the local device. 
15.  After viewing the confirmation message, click Next. 
Configure Remote Device Port Settings 
The port settings on the remote device, such as baud rate and 
parity, are the same as those set in the local device configuration. 
16.  Confirm that the port settings for the remote port are the 
same as the settings for the local, with the exception of 
the DTE/DCE setting, which will be the opposite. 
17.  Click  Advanced to configure the Output Power Level 
or the  SPP  Connect Output Select  (if remote port is 
configured as a DCE device) as in the previous screen. 
18.  When all selections are specified, click  Set  Port 
Configuration to send settings to the remote device. 
19.  After viewing the confirmation message, click Next. 
20.  While in the Save Configuration Settings, click Save to 
store the settings. The settings are stored in the unit 
until it is reconfigured. 
21.  Turn off both Wavespeed/S units by sliding the three 
position switch to the middle position for two seconds. 
22.  Place both Wavespeed/S units in the On mode, by 
sliding the three position switch back to the left (toward 
the power connector). 