Specifications

Wavespeed/S Configuration Guide (90000407 Rev. C) Page 11
EN 55022 Class B (1994 w/A1 1995)
Test Specification
EN55022
Requirement
Radiated
Emissions
Class B
Conducted
Emissions
CISPR 22 Class B
EN55024 (1998)
Test Specification
EN55024
Requirement
Electrostatic
Discharge
EN61000-4-2
+4 kV contact
+8kV air
Radiated
Immunity
EN61000-4-3 3 V/m
Electrical Fast
Transient
Burst
EN61000-4-4
1kV (A/C), .5kV
(I/O)
Surge EN61000-4-5
2kV common
mode
1kV differential
mode
Conducted
Immunity
EN61000-4-6 3V rms
Magnetic
Immunity
EN61000-4-8
1 A/m Not
Applicable
Voltage Dips
& Interrupts
EN61000-4-11
>95%, 30% &
>95%
EN61000-3-2 (2000)
Test Specification
EN61000-3-2
Requirement
Limits for
harmonic
current
emission
Class B
EN61000-3-3 (1995)
Test Specification
EN61000-3-3
Requirement
Limitation of
voltage
fluctuation
and flicker
European Contact
Digi International
Joseph-von-Fraunhofer Str. 23
44227 Dortmund, GERMANY
49-231-9747-0
UL/CSA Safety Information
This device complies with the requirements of
following safety standards below:
UL 1950, 3rd edition
CSA No. 950
Quality Manager
Austin, Texas
July 2006
Digi International
11001 Bren Road East
Minnetonka, MN 55343
digi.info@digi.com
www.digi.com
Corporate
Headquarters:
952-912-3444
877-912-3444
Fax: 952-912-4952
Digi Europe: +49-231-9747-0
Digi Hong Kong: +852-2833-1008
Digi North America: 877-912-3444