170 Chapter 2 Command Descriptions
autoservice={default|raw|rlogin|telnet}
Specifies the autoconnection service for this port, which is only used if
"auto=on." Choose one of the following:
default
Normally means the Digi device uses the Telnet service. The
exception is if the "dport" option is 0 or 513. In that case, "rlogin" is
used.
raw
Data is passed between the serial port and the TCP stream without
modification.
rlogin
The Digi device uses the remote login (rlogin) service.
telnet
The Digi device uses the Telnet service.
bin={on|off}
Determines whether Telnet users of the port are provided with Telnet
binary connections.
on
Telnet users are provided with Telnet binary connections.
off
Telnet users are provided with normal (ASCII) connections.
The default is "off."
dest={ip adr|none
The IP address of the destination system to which port users will be
routed if "auto=on." To disable this option, specify "none."
dev=device
The device type, which defines the device connected to the port.
Typically, you can use the following to define the devices listed. The
default is “term.”
For most: Use this dev=device value
Power units dev=power
Most printers dev=prn
Most dumb terminals dev=term
Most incoming modem connections dev=min
Most outgoing modem connections dev=mout
Most bidirectional modem connections dev=mio
Most RealPort connections dev=rp
Most reverse Telnet connections dev=prn
Modem emulation dev=pm
Industrial Automation (IA) dev=ia