User guide

set flow
Chapter 2 Command Descriptions 117
altpin={on|off}
Determines whether the altpin option, which swaps DCD with DSR so
that eight-wire RJ-45 cables can be used with modems, is used:
on
The altpin option is used.
off
The altpin option is not used.
The default is "off."
cts={on|off}
Determines whether CTS (clear to send) is used for output flow control:
on
CTS is used for output flow control.
off
CTS is not used for output flow control.
The default is "off."
dcd={on|off}
Determines whether DCD (data carrier detect) is used for output flow
control:
on
DCD is used for output flow control.
off
DCD is not used for output flow control.
The default is "off."
dsr={on|off}
Determines whether DSR (data set ready) is used for output flow control.
on
DSR (data set ready) is used for output flow control.
off
DSR is not used for output flow control.
The default is "off."
dtr={on|off}
Determines whether DTR (data terminal ready) is used for input flow
control.
on
DTR is used for input flow control.
off
DTR is not used for input flow control.
The default is "off."