User guide
set flow
116 Chapter 2 Command Descriptions
set flow
Device support This command is supported in all devices.
Purpose Configures or displays flow control options for the device server’s EIA-232
serial ports. Several options related to the RTS toggle feature are hidden
by default, and can be displayed by using the “show=rtstoggle” option.
Required
permissions
The root user can configure flow control options. Normal users can display
flow control options.
Syntax Configure flow control options
set flow [aixon={on|off}]
[altpin={on|off}]
[cts={on|off}]
[dcd={on|off}]
[dsr={on|off}]
[dtr={on|off}]
[forcedcd={on|off}]
[itoss={on|off}]
[ixany={on|off}]
[ixoff={on|off}]
[ixon={on|off}]
[pre-delay=milliseconds]
[post-delay=milliseconds]
[range=range]
[ri={on|off|power}]
[rts={on|off|toggle}]
Display flow control options
set flow [range=range]
Display hidden RTS toggle flow control options
set flow [range=range] show=rtstoggle
Options aixon={on|off}
Determines whether the auxiliary flow control characters defined on the
"set keys" command are used for output flow control:
on
Auxiliary flow control characters are used.
off
Auxiliary flow control characters are not used.
The default is "off."