User`s guide
71
priority is greater than 0 and an event of this priority or higher occurs. SMS alarms may be
configured using the Configuration - Alarms > Event Settings > SMS web page
If no number is specified it is possible that the unit will operate using the default message
centre for the GSM service to which you have subscribed.
SMS access level:
The access level for SMS commands. The access level set here will need to match the level
required by the command sent by SMS for the command to be accepted.
Use x as a command separator (default is CR)
This parameter specifies the character to be used to separate multiple command lines when
a remote SMS sender is controlling the unit. The default separator is <CR> but some SMS
capable devices are not equipped with <CR> keys so an additional means of separating
multiple lines is required.
Allow CLI commands from the following SMS numbers.
You may specify up to 10 numbers. Specifying * permits commands from any SMS number.
Numbers are applied in the following input box. Click ‘Add’ to submit
Related CLI Commands - SIM Slot 1 (PPP 1)
Entity
Instance
Parameter
Values
Equivalent Web Parameter
modemcc 0 sms_interval
Poll for incoming SMS
messages:-
Every n minutes
modemcc 0 sms_replies on/off
Enable command replies via
SMS
modemcc 0 sms_concat
Number
0 = off
10 = default when
enabled
Concatenate replies
modemcc 0 sca Free text field
Use this SMS message centre
number n instead of the
network default
modemcc 0 sms_access
0 = Super (default)
1 = High
2 = Medium
3 = Low
4 = None
5 = HighLow
6 = HighMedium
7 = CheckPar
SMS access level:
modemcc 0 sms_cmd_sep Free text field
Use as a command
separator (default is CR)