User`s guide

285
Controls the automatic generation of a [CR],[LF] sequence after a certain line width has
been reached.
Option
Description
0 No line folding
1 - 255 Width of line before the PAD generates [CR],[LF]
11 Port Speed
This is a “read only” parameter, set automatically by the PAD and accessed by the remote
system.
Option
Description
15 19,200 bps
14 9,600 bps
12 2,400 bps
3 2,400 bps
12 Flow Control of PAD (by DTE)
Determines the flow control setting of the PAD by the DTE in the on-line data state.
Option
Description
0 No flow control
1 XON/XOFF flow control
3 RTS/CTS flow control (not a standard X.3 parameter)
13 LF Insertion (after CR)
Controls the automatic generation of a Line Feed by the PAD.
Option
Description
0 No line feed insertion
1 Line Feeds inserted in data passed TO the DTE
2 Line Feeds inserted in data received FROM the DTE
4 Line Feeds inserted after CRs echoed to DTE
The line feed values can be added together to select Line Feed insertion to any desired
combination.
14 LF Padding
Some terminal devices such as printers require a delay after each Line Feed before they can
continue to process data. This parameter controls the number of padding characters (NUL -
ASCII 0) that are sent after each [LF] to create such a delay.
Option
Description
0 No line feed padding.
1 - 255 Number of NUL characters inserted after LF
15 Editing