User`s guide

281
Entity Instance Parameter Values
Equivalent Web
Parameter
pad n iphdr
0=Off, 1=On, 2=8583 Ascii
4 byte
IP length header
pad n prompt text PAD prompt
pad n padmode
0 = Normal, 1 = Prompt
Always On
PAD mode
pad n profile 1-4, 50, 51,90,91 Use PAD Profile
pad n strip_tspaces 1 = enabled, 0 = disabled Strip Trailing Spaces
pad n llmode 1 = enabled, 0 = disabled Enable Leased Line Mode
pad n enqcon 1 = enabled, 0 = disabled Send ENQ on Connect
pad n stxmode 1 = enabled, 0 = disabled
Enable STX / ETX Filtering
pad n delconmsg 0 - 10
Delay connect message n
x 10 millisecondss
pad n data_del 0 - 2147483647
Delay data transfer after
connection by n x 10
milliseconds
pad n inacttim 0 - 1000
Terminate the PAD call
after x seconds if there
has been no data
transmission
pad n nocalltim 0 - 60000
Disconnect the layer 2 call
if there is no layer 3 call in
progress for x seconds
pad n trig_str text
Create an event when the
following data is on the
PAD
pad n inactevent 0 - 2147483647
Create an event when
there has been no activity
on the PAD for x seconds
Stopping and starting PADs
PAD instances can be stopped and started using the following CLI commands:
stoppads
gopads
The stoppads command stops all PAD instances from accepting and performing any PAD
commands.
The gopads command resumes processing of PAD commands.
The stoppads and gopads commands can have the PAD number specified in the syntax to
stop and start individual PAD instances.
For example:
To stop PAD 1 from processing PAD commands: