User`s guide
113
Data Bits / Parity
This drop-down selection box selects the required data format for the interface, 8 data bits,
no parity being a very common configuration.
Note:
When the serial port is not in 8-bit parity mode (i.e. it is in either 8-bit no parity, or 7-bit
with parity), the router will continually check for parity when receiving AT commands and
adjust and match accordingly.
Flow Control
The unit supports software flow control using XON/XOFF characters and hardware flow
control using the RS232 RTS and CTS signals. Use this drop-down list to select “Software”,
“Hardware” or a combination of “Both”. To disable flow control select the “None” option.
Enable echo on this interface
Check this checkbox to enable command echo to be enabled when using the command line
interpreter, uncheck it if the attached terminal provides local echo.
CLI result codes
Select the required level of verbosity for command result codes. The available options are:
• Verbose
• Numeric
• None.
Related CLI Commands
Entity
Instance
Parameter
Values
Equivalent Web Parameter
asy n/a descr
Free text –
description of
interface
Description
S31=n n/a n/a
Where n =
3 = 115200
4 = 57600
5 = 38400
6 = 19200
7 = 9600
8 = 4800
Baud rate
S23=n n/a n/a Data Bits / Parity
&Kn n/a n/a
Where n =
0 = None
1 = Hardware
2 = Software
3 = Both
Flow Control
&En n/a n/a
Where n =
0 = No echo
1 = echo
Enable echo on this interface
&Vn n/a n/a
Where n =
0 = numeric
1 = verbose
CLI result codes