User`s guide

105
Entity
Instance
Parameter
Values
Equivalent Web Parameter
seconds
ppp n timeout2 0 2147483648
Alternative idle timer for static
routes s seconds
ppp n rxtimeout 0 2147483648
if the link has not received any
packets for s seconds
ppp n maxneg 0 2147483648
if the negotiation is not
complete in s seconds
ppp n uplogmins 0 2147483647
Generate an event after this
interface has been up for m
mins
ppp n dlwarnkb 0 2147483647 Issue a warning after n units
ppp n dlstopkb 0 2147483647
Stop data from being
transmitted after n units
ppp n dlrstday 0 255
Reset the data limit on the n
day of the month
DialServ
Configuration – Network > Interfaces > DialServ
The Dialserv option module mimics a telephone exchange in that it supplies the required
voltages on the line, generates a RING signal and has off-hook detection circuitry. It can be
used to provide similar functionality to dialling into an ISP using an analogue MODEM. The
card also contains an analogue MODEM to handle data on the line.
Use PPP/Protocol Switch
These radio buttons select whether the DialServ card uses a PPP instance or the protocol
switch functionality to control traffic on the interface. If PPP is selected, the web page
expands to reveal the standard PPP configuration settings. If Protocol Switch is selected,
only the four settings described immediately below are visible.
Max time to RING line s seconds
The value in this text box specifies the maximum number of seconds that the RING signal
should be generated for.
RING frequency n Hz
The DialServer module generates a RING signal the frequency of the RING is selected
from this drop-down list. The available options are:
20Hz
25Hz
30Hz
40Hz
50Hz.
Initialisation string 1
The text string in this text box contains any required MODEM initialisation commands.
Initialisation string 2
The text string in this text box contain initialisation commands that will be issued to the
MODEM after the first initialisation string.