User`s guide
293
Idle Gap
When receiving an modbus response from a station when this idle gap (pause with no
reception of characters) is detected the message (currently received from the station) is at
that staged forwarded on as the complete response.
Fix slave address
The address of the slave is fixed at this value. An address conversion will take place if a
message that does not contain this address is received from the TCP master. If not used
the TCP master must use the correct slave address.
Adjust slave address
The address of the slave is adjusted by this value. If left to zero then the slave address is
not adjusted at all.
Related CLI Commands
Entity Instance Parameter Values
Equivalent Web
Parameter
modbus n enabled
1 = enabled, 0 =
disabled
Enable MODBUS
Gateway
modbus n asy_add 0 - 255 Async Port
modbus n async_mode RS322 or RS422 Async Mode
modbus n duplex 0 = full, 1 = half Duplex Mode
modbus n idle_gap 0 - 2147483647 Idle Gap
modbus n fix_slave_address 0 - 255 Fix slave address
modbus n adj_slave_address 0 - 255 Adjust slave address
modbus n ipport0 0 - 65535 IP Port (row 1)
modbus n nbsocks0
0 - “currently
available”
Number of sockets (row
1)
modbus n ipmode0 0 = TCP, 1 = UDP IP Mode (row 1)
modbus n rawmode0
1 = enabled, 0 =
disabled
Raw Mode (row 1)
modbus n Ipport1 0 - 65535 IP Port (row 2)
modbus n nbsocks1
0 - “currently
available”
Number of sockets (row
2)
modbus n ipmode1 0 = TCP, 1 = UDP IP Mode (row 2)
modbus n rawmode1
1 = enabled, 0 =
disabled
Raw Mode (row 2)