8 Discard Output
This parameter determines whether data received during a call is passed to the DTE or
discarded. It can only be directly set by the remote system and may be used in a variety of
circumstances when the remote DTE is not able to handle a continuous flow of data at high
speed.
Option
Description
0 Normal data delivery to DTE
1 Output to DTE discarded
9 Padding after CR
Slower terminal devices, such as printers, may require a delay after each Carriage Return
before they can continue to process data. This parameter controls the number of pad
characters (NUL - ASCII 0) that are sent after each CR to create such a delay.
Option
Description
0 No padding characters after CR
1 - 255 Number of padding characters (NUL) sent after CR
10 Line Folding
Controls the automatic generation of a [CR],[LF] sequence after a certain line width has
been reached.
Option
Description
0 No line folding
1 - 255 Width of line before the PAD generates [CR],[LF]
11 Port Speed
This is a “read only” parameter, set automatically by the PAD and accessed by the remote
system.
Option
Description
15 19,200 bps
14 9,600 bps
12 2,400 bps
3 2,400 bps
12 Flow Control of PAD (by DTE)
Determines the flow control setting of the PAD by the DTE in the on-line data state.
Option
Description
0 No flow control
1 XON/XOFF flow control
3 RTS/CTS flow control (not a standard X.3 parameter)