User`s guide
134
Entity
Instance
Parameter
Values
Equivalent Web Parameter
ppp n sub up to 17 digits
with ISDN sub-address ending
with n
ppp n maxup 0 – 2147483648
Close the PPP connection after s
seconds
ppp n maxuptime 0 – 2147483647
if it has been up for m minutes
in a day
ppp n timeout
Default 300s (5
minutes)
if it has been idle for h, m, s
ppp n timeout2 0 – 2147483648
Alternative idle timer for static
routes s seconds
ppp n rxtimeout 0 – 2147483648
if the link has not received any
packets for s seconds
ppp n maxneg 0 – 2147483648
if the negotiation is not
complete in s seconds
ppp n do_nat
0,1
0 = Off
1 = On
Enable NAT on this interface
ppp n natip
Valid IP address
a.b.c.d
NAT Source IP address a.b.c.d
ppp n ipsec
0,1
0 = Off
1 = On
Enable IPsec on this interface
ppp n ipsecent
Default
PPP
Ethernet
Use interface x,y for the source
address of IPsec packets
ppp n ipsecadd
Valid interface
number
Use interface x,y for the source
address of IPsec packets
ppp n firewall OFF, ON
Enable the firewall on this
interface
Configuration – Network > Interfaces > Advanced > PPP n > Mobile
Mobile telephone modules fitted into the router use PPP to connect to the network and send
and receive traffic. This section describes parameters relevant to setting up a mobile
telephone module.
Use SIM Any, SIM1, SIM2
These radio buttons are used to select which of the SIM cards fitted should be used by the
module.
Detach W-WAN if the link fails
When checked, this checkbox will cause the router to issue the command to detach the
mobile telephone module from the wireless network if it detects that the link has failed. Link
failure is detected by a PPP ping response timer or by a firewall request.