User`s guide

117
Configuration Network > Interfaces > Serial > Serial Port n > Profiles
Each serial port can have two profiles which can be configured differently. Which profile is in
force when the router powers-up is selected here.
Power-up profile n
Select “0” from the drop-down selection box to choose profile 0 to be active when the router
powers-up. Select “1” from the selection box to make profile 1 the active profile.
Load Profile n
Select “0” from the drop-down selection box and click the button to load profile 0.
Save Profile
Select “0” from the drop-down selection box and click the button to save profile 0 after
making any changes.
Related CLI Commands
Entity
Instance
Parameter
Values
Equivalent Web Parameter
&Yn
Where n =
0,1
Power-up profile n
&Zn
Where n =
0,1
Load Profile n
&Wn
Where n =
0,1
Save Profile n