Technical data

Page 50 Command Reference
onlcr=on|off
Use to map (ON) or not to map (OFF) NEWLINE characters to CR-NEWLINE on
output. Default=off
otab=on|off
Converts output tabs to eight spaces. Default= off
parity=O|E|N
Use to select Odd, E
ven or No parity. Default=N (no parity).
range=startport#-endport#
Specify a range of ports to be modified.
save=on|off
Save the changes to EEPROM.
stopb=1|2
Use to set the Stop Bits to 1 or 2. Default=1
logins
Syntax: set logins option=value
Use this command to activate/deactivate login and password protection, define prompts and
startup messages. set logins range= is used to specify multiple ports, or one specific port.
Options are:
cmdprompt logprompt login write
passprompt passwd range save
verbose
Character Strings
Many of the values entered for logins are character strings. To include a space in a character
string, enclose the entire string in quotation marks. For example, to change the PortServer
login prompt to Enter login:,type:
set logins logprompt="Enter login:"
Each of the preceding will have their own options, as outlined in the following descriptions.
(More than one option can be included in a command.)