Technical data
PortServer Terminal Server Page 49
xona=value
Use to set the auxiliary XON Character you prefer. Default=^Q (<Ctrl-Q>)
xoffa=value
Use to set the auxiliary XOFF Character you prefer. Default=^S (<Ctrl-S>)
line
Syntax: set line option=value
Use line to view or modify serial line parameters. Use set line range= to specify a single
port or group of ports. Options are:
baud break csize error inpck istrip
onlcr otab parity range save stopb
Each of the preceding will have their own options, as outlined in the following descriptions.
(More than one option can be included in a command.)
baud=baudrate
Usetosetthebaudratefortheport.Legalvaluesare:
50 600 3600 19200
110 1200 4800 38400
150 1800 7200 57600
300 2400 9600
break=ignore|send|escape
Used to ignore (default), or send an escape sequence when a telnet break command
is seen.
csize=5|6|7|8
Sets the Character size. Can be 5, 6, 7 or 8 bits per character. Default=8
error=ignore|null|parmk|dos
Tells the PortServer software what to do with parity errors. It can ignore the error
(default), change the error character to a null, or mark the error with an FF.
inpck=on|off
Turn on or off input parity checking. Default=off
istrip=on|off
When ON, strips the high order bit in each byte. Default= off