User`s guide
Configure Physical Serial Ports
Chapter 5  Configure Ports  67
Recommended sequence for configuring port settings
If using the Basic and Advanced configuration settings to configure serial 
ports, the sequence is:
1. In the Web interface for the the Digi Passport unit, go to 
Serial Port > Configuration. 
2. Before connecting any serial devices to the Digi Passport unit, 
configure the Automatic Detection feature. On the Configuration page, 
click Port automatic detection configuration. Create a port automatic 
detection list, which is a set of common serial port characteristics used 
to determine which kind of device is attached to the Digi Passport unit, 
such as baud rate, data, parity, stop bits, and a string sent to the device 
to detect its operating system and host name. The port automatic 
detection list is used as probe criteria when Automatic Device 
Recognition is activated and the serial ports are tested. For more 
information on Automatic Detection settings, see "Configure Automatic 
Detection" on page 77. Here is a typical example of probe criteria.
3. Click Save & apply.
4. Enable Automatic Detection for all ports: In the serial ports view 
(Serial Port > Configuration), click All to select all ports. Change the 
Automatic Detection setting from Off to Active.
5. Click Save & apply.
6. As needed, change configuration settings for individual ports, using 
either Basic configuration or Advanced configuration settings. 
Basic configuration settings are described on page 68. Advanced 
configuration settings are described on page 92.










