User manual
Configuration through the web interface
126
Hardware reset thresholds
 Hard reset the modem module after the following number of consecutive 
failed connections: Enables or disables a hard reset of the cellular modem 
module after the specified number of failed connection attempts.This value can 
be a number between 1 and 255. The default is 3. 
 Power-cycle the device after the following number of consecutive failed 
connections: Enables or disables a power-cycle of the Digi device after the 
specified number of failed connection attempts. This value can be a number 
between 1 and 255. The default is 0, or off.
Link integrity monitoring settings
 Enable Link Integrity Monitoring using the test method selected below: 
Enables or disables the link integrity monitoring tests. If this setting is enabled, 
the other Link Integrity Monitoring settings may be configured and are used to 
verify the functional integrity of the mobile connection. The default is off 
(disabled). 
There are three tests available: 
–Ping Test 
– TCP Connection Test 
– DNS Lookup Test 
You can use these tests to demonstrate that two-way communication is working 
over the mobile connection. Several tests are provided because different mobile 
networks or firewalls may allow or block Internet packets for various services. 
Select the appropriate test may be selected according to mobile network 
constraints and your preferences. 
The link integrity tests are performed only while the mobile connection is 
established. If the mobile connection is disconnected, the link integrity tests are 
suspended until the connection is established again. 
For the link integrity tests to provide meaningful results, the remote or target 
hosts must be accessible over the mobile connection and not through the LAN 
interface of the device (if it has one). That is, the settings should be configured 
to guarantee that the mobile connection is actually being tested. 
The link integrity test settings may be modified at any time. The changes are 
used at the start of the next test interval. 