User manual
80 Chapter 19 Reference and Certifications
Device Server EIA 232/422/485 Switch Settings
RJ-45 Pinouts
WARNING: To prevent electric shock, do not remove the cover of this
module while unit is powered up. There are no user-serviceable parts
inside. Refer servicing to qualified personnel.
CAUTION: This unit has two power inputs. For total isolation from electrical
shock and energy hazard, disconnect both power inputs. The device is
intended to be mounted in an indoor only type system.
Function
Switch Settings
1 2 3 4
EIA-232 Up Down Down Down
EIA-422/485 Full-duplex Down Up Down If up, termination.
If down,
no termination
EIA-485 half-duplex Down Down Up
RJ-45
Pin
EIA-232
EIA-422/485
Full-Duplex
EIA-485 Half-
Duplex
1 RI TxD- TxD-
2 DSR RxD- RxD-
3RTS RTS+ NA
4 GND GND GND
5 TxD TxD+ TxD+
6 RxD RxD+ RxD+
7SG SG SG
8CTS CTS+ NA
9DTR RTS- NA
10 DCD CTS- NA