set surelink
206 Chapter 2 Command Descriptions
max_consecutive_failures={1-255, 0=off} (probe failures before link
reset)]
The maximum number of consecutive Link Integrity Monitoring tests.
After this number is reached, the mobile connection should be
disconnected and reestablished.
This value must be between 1 and 255. The default is 3. A value of 0 turns
off this feature. When the mobile connection is reestablished, the
“consecutive failures” counter is reset to zero.
Note: if the mobile connection is disconnected for any reason (including
not as a result of a link integrity test failure), the consecutive failures
count is reset to zero when the mobile connection is reestablished.
interval=10-65535
Specifies the interval, in seconds, at which the selected Link Integrity
Monitoring test is initiated or repeated. A new test will be started every
specified number of seconds while the mobile connection is
established. This value must be between 10 and 65535. The default is
240.
If the configured interval is less time than it takes a test to complete,
the next test will not be initiated until the previous (current) test has
completed.
ICMP ping link test options
pingaddr1={ipv4 address|fqdn}
The first host to test.
pingaddr2={ipv4 address|fqdn}
The second host to test, if the first host fails.
TCP connection link test parameters:
ipaddr1={ipv4 address|fqdn}
The first host to test.
ipaddr2={ipv4 address|fqdn}
The second host to test, if the first host fails.
ipport=1-65535
The TCP port number to connect to on the remote host. The default is 80.
DNS lookup link test parameters
dnsfqdn1=dns fqdn
The first hostname to look up.
dnsfqdn2=dns fqdn
The second hostname to look up, if the first hostname fails.
Example set surelink system_reset_connect_failures=30