User manual

set surelink
Chapter 2 Command Descriptions 203
Set TCP connection link test parameters:
set surelink [ipaddr1={ipv4 address|fqdn}]
[ipaddr2={ipv4 address|fqdn}]
[ipport=1-65535]
Display current SureLink settings
set surelink
Options Options for Hardware reset thresholds
module_reset_connect_failures={1-255|0=off}
The number of failed connection attempts that occur before the cellular
modem module is reset. This value can be a number between 1 and 255,
or 0, which turns off the cellular modem module-reset feature. The default
is 3.
system_reset_connect_failures={1-255|0=off}
The number of failed connection attempts that occur before the Digi
Cellular Family device is reset. This value can be a number between 1
and 255, or 0, which turns off the system-reset feature. The default is 0,
or off.
Options for Link Integrity Monitoring Tests
General link test options:
state={on|off}
Enables or disables link integrity monitoring tests. If “on,” the other Link
Integrity Monitoring settings may be configured and are used to verify the
functional integrity of the mobile connection. The default is “off.”