Installation guide
51
set alarm
Purpose Configures device alarms and display current alarm settings. Device alarms
are used to send emails or SNMP traps when certain device events occur.
These events include data patterns detected in the serial stream.
To avoid false errors, configure alarms while alarms are disabled, by entering a
“set alarm state=off” command, then enable alarms after they are fully
configured by entering “set alarm state=on”.
Required permissions For products with two or more users, permissions must be set to “set
permissions s-alarm=read” to display current alarm settings, and to “set
permissions s-alarm=rw” to display alarm settings and configure alarms. See
"set permissions" for details on setting user permissions for commands.
Syntax Configure alarms with general options (applies to all alarms)
set alarm [state={on|off}]
Configure alarms for a range (set multiple alarms)
set alarm range={1-32}
[active={on|off}|to=string|cc=string|subject=string
|priority={normal|high}|type={email|snmptrap|all}]
Configure alarms based on data pattern matching
set alarm port=1-16
match=string
Display current alarm settings
set alarm [range={1-32}]