Installation guide

144
set switches
Purpose Configures Multiple Electrical Interface (MEI) settings on a per-port basis,
and displays current MEI settings. MEI settings include the type of electrical
interface (EIA-232 or EIA-485), the number of differential wires used for
communication, and whether termination and biasing resistors are used.
Required permissions The serial permissions associated with the "set serial" command also apply to
this command. For products with two or more users, to use this command,
permissions must be set to one of the following.
For a user to display the serial settings for the line on which they are
logged in: “set permissions s-serial=r-self”
For a user to display the serial settings for any line:
“set permissions s-serial=read”
For a user to display and set the serial settings for the line on which
they are logged in: “set permissions s-serial=rw-self”
For a user to display the serial settings for any line, and set serial
settings for the line on which the user is logged in:
“set permissions s-serial=w-self-r”
For a user to display and set the serial settings on any line:
“set permissions s-serial=rw”
See "set permissions" for details on setting user permissions for commands.
Syntax Configure MEI settings
set switches [port=range]
[mode={232|485}]
[wires={two|four}]
[termination={on|off}]
Display current MEI settings
set switches