User`s guide
95
Configuring the Digi Connect Devices
– Every: The number of seconds the pins must remain in the defined state for a
reminder to be sent.
Send alarms based on serial data pattern matching: Click this radio button to
specify that this alarm is sent when the specified serial data pattern is detected.
Then specify the following:
– Serial Port: The serial port to monitor for the data pattern. This field is
displayed for devices where more than one serial port is available.
– Pattern: An alarm is sent when the serial port receives this data pattern. You can
include special characters such as carriage return carriage return (\r) and new
line (\n) in the data pattern.
Alarm Destinations
The Alarm Destination part of the page defines how alarm notifications are sent—either
as an email message or an SNMP trap, or both—and where the alarm notification is sent.
Send E-mail to the following recipients when alarm occurs: Select the
checkbox to specify that the alarm should be sent as an email message. Then
specify the following information:
– To: The email address to which this alarm notification email message will be
sent.
– CC: The email address to which a copy of this alarm notification email
message will be sent (optional).
– Priority: The priority of the alarm notification email message.
– Subject: The text to be included in the Subject: line of the alarm-notification
email message.
Send SNMP trap to the following destination when alarm occurs: Select the
checkbox to specify that the alarm should be sent as an SNMP trap.
For alarms to be sent as SNMP traps, the IP address of the destination for the
SNMP traps must be specified in the SNMP settings. This is done on the
System Configuration pages of the default web interface. See "Configure
SNMP" on page 97. That destination IP address is then displayed below the
“Send alarm to SNMP destination” checkbox.
To configure an alarm notification to be sent as both an email message and an
SNMP trap, select both “Send E-Mail” and “Send SNMP trap” checkboxes.
Click Apply to apply changes for the alarm and return to the Alarms
Configuration page.