User`s guide
Features
28
Digi Connect Family User’s Guide
Note
The Digi Connect ME and Digi Connect Wi-ME modules use a supervisor
circuit with a 2.88 reset threshold and an internal 5k pull-up resistor. When
VCC falls to the threshold voltage, a reset pulse is issued, holding the
output in active state. When power rises above 2.88V, the reset remains for
approximately 250 ms to allow the system clock and other circuits to
stabilize.
Note
The Digi Connect EM and Digi Connect Wi-EM modules use a supervisory
circuit with a 2.93V reset threshold. When VCC falls to the threshold
voltage, a reset pulse is issued, holding the output in active state. When
power rises above 2.93V, the reset remains for approximately 200 ms to
allow the system clock and other circuits to stabilize.
Network Interface Features
Key features of the network interface for Digi Connect products are as follows:
Standard:
– IEEE 802.3 for Digi Connect SP, Digi Connect ME, Digi Connect EM, Digi
Connect WAN, and Digi Connect RG.
– IEEE 802.11b for Digi Connect Wi-SP, Digi Connect Wi-ME and Wi-EM.
Physical layer: 10/100 Mbit Base-T for Digi Connect SP, Digi Connect ME,
Digi Connect EM, Digi Connect WAN, and Digi Connect RG.
Network data rate:
– 10 Mbps/100 Mbps, with auto-sensing of speed for Digi Connect SP, Digi
Connect ME, Digi Connect EM, Digi Connect WAN, and Digi Connect RG.
– Up to 11 Mbps with automatic fallback for Digi Connect Wi-SP Digi Connect
Wi-ME and Wi-EM.
GPIO Outputs
Symbol Description Min Typ Max Unit
V
OH
Output High Voltage 2.4 — 3.45 V
V
OL
Output Low Voltage 0 — 0.4 V