74 Chapter 2 Command Descriptions
set mgmtconnection
Devices
supported
This command is supported in all Digi Connect Family devices.
Purpose Used to set or display the Connectware Device Protocol connection
settings.
Required
permissions
To use this command, permissions must be set to one of the following:
• For a user to display the Connectware Device Protocol connection
settings: “set permissions s-mgmtconnection=read”
• For a user to display and set Connectware Device Protocol connection
settings: “set permissions s-mgmtconnection=rw”
See "set permissions" on page 86 for details on setting user permissions
for commands.
Syntax Configure Connectware Device Protocol connection settings
set mgmtconnection [connenabled={on|off}]
[conntype={client|timed|serverinitiated}]
[timedperiod=period]
[timedoffset={immediate|oneperiod|randomtime}]
[lkaupdateenabled={on|off}]
[clntreconntimeout={none|timeout]
[svraddr[1-8]=string]
[secidx[1-8]=index]
Display Connectware Device Protocol connection settings
set mgmtconnection
Options connenabled={on|off}
Used to specify whether or not this instance is enabled for use.
on
Enables this instance for use.
off
Disables this instance for use.
conntype={client|timed|serverinitiated}
Used to specify the connection type.
client
This is a client connection.
timed
This is a timed connection.
serverinitiated
This is a server-initiated connection.