Installation guide
set ethernet
60 Chapter 2 Command Descriptions
set ethernet
Devices
supported
This command is supported in Digi Connect SP, Digi Connect EM, and
Connect ME devices.
Purpose Configures, adjusts, and displays Ethernet communications parameters.
Required
permissions
Permissions must be set to “set permissions s-ethernet=read” to display
Ethernet communications parameters, and “set permissions s-ethernet=rw”
to display and configure Ethernet communications parameters. See "set
permissions" on page 86 for details on setting user permissions for
commands.
Syntax Configure Ethernet communications parameters
set ethernet [duplex={half|full|auto}] [speed={10|100|auto}]
Display Ethernet communications parameters
set ethernet
Options duplex
Determines the mode the Digi device uses to communicate on the
Ethernet network. Specify one of the following:
half
The device communicates in half-duplex mode.
full
The device communicates in full-duplex mode.
auto
The device senses the mode used on the network and adjusts
automatically.
The default is “half.” If one side of the Ethernet connection is using auto,
the other side can set the duplex value to whatever is desired. If one
side uses a fixed value (for example, half-duplex), the other side has to
use the same.