Installation guide
set alarm
Chapter 2 Command Descriptions 47
Options Options for setting alarms with general options
from=string
The text to be included in the “from” field of an alarm-triggered email.
mailserverip=ipaddress
Used to configure IP address of the mail server to which alarm-triggered
emails are sent.
state= {on|off}
Enables or disables all alarms.
on
Enables all alarms.
off
Disables all alarms.
The default is “off.”
Options for setting alarms with a range (set multiple alarms)
The following options apply to setting multiple alarms using a “range”
option.
range= {1-n}
All alarm options require a “range” option that is used to select the alarm
or range of alarms to set the options on. This “range” option is used to
specify the indices of the alarms to which the other options will be
applied.
active={on|off}
Enables or disables an alarm.
on
Enables an alarm.
off
Enables an alarm.
The default is “off.”
cc=string
The text to be included in the “cc” field of an alarm triggered email.
mode={match|gpio}
The alarm mode, which determines what type of event will trigger an
alarm.
match
Specifies that an alarm will be triggered when a pattern is found in the
stream of serial data.
gpio
Specifies that the transitions for GPIO pins will trigger alarms. See
"Options for setting alarms in GPIO mode" on page 49 for more
information about GPIO.
The default is “gpio” for all Digi Connect devices except Digi Connect SP.
For Digi Connect SP, the only option available is “match.”